The operating principle of a central drum humidifier (drum) is as follows: a sponge fixed on a drum rotates on itself by absorbing water in a tub. The blower blows on the sponge, projecting the moisture into the central system. We use the Generalaire 81 drum humidifier.


PRE-REQUIREMENT FOR INSTALLATION:

 

  • A blown air furnace with air ducts.
  • A water supply in the furnace chamber. We install a self-piercing valve on a cold water pipe in the furnace chamber and connect this pipe to the humidifier with a hose.
  • Does not require drain, as the water evaporates in the sponge. Using a fleet, water replenishes in the retention tank as required.
  • We use the 24 volt from the furnace for the power supply of the humidifier.

 

 

HUMIDIFIER MAINTENANCE:

The maintenance required is minimal, you must replace the sponge and clean the holding tank once a year. Here is a video explaining how to do it:

 



MARQUE: GENERALAIRE

MODEL: GENERALAIRE 81



GENERALAIRE 81
GENERALAIRE 81





Climatisation chauffage central

GENERALAIRE 81 HUMIDIFIER CHARACTERISTICS

  • -
    Manual humidistat.
  • -
    Drum humidifier.
  • -
    Ideal product for homes under 2000 square feet.
  • -
    Easy access drum.
  • -
    Warranty of one year on labor and 5 years on parts.